HF-Kabel
& HF-Verbinderseit
2002
Inh. K. Kusch
Tel. 0231
25 72 41 Fax 0231
25 23 99
E-mail: info@kabel-kusch.de
www.Kabel-kusch.de
Hyperflex 10
Preisliste für
Kabel - prtices of cables
Hyperflex 10 |
weitere Informationen über das
Verhalten von Hyperflex 10 bei häufigen Biegungen
more informations
about characteristics after intensiv bendings
TEST REPORT
Laboratory tests and
measurements
Technician
Roberto Moroni
DATE : 23/03/17
Test Instruments :
• VNA Copper Mountain Planar 804/1
Multiple bending test on cable
Hyperflex 10
Test performed at the temperature of 20°C.
This test must be regarded as a
test led to the limits of a reasonable use of the product.
When installing the cable for use with motorized antennas, it is strongly
recommended to consider
much wider bends in order to obtain a long lasting operative life,
efficiency and performance.
A) Test performed on a 100 mm
bending radius, (9 Metres Cable Length).
Graph Before the bendings
A) Graph showing behaviour of the cable after 100 bendings on a 100mm bending radius
A) The impedance and Structural
Return Loss (SRL) don’t show any significant variation, The
attenuation doesn’t change as well.
B) Test on a 80 mm bending radius : cable length 7,5 m graph before the test
B) The
attenuation at 2.4 GHz increases by 0.1 dB, although no variation on
Impedance stability and SRL is
noticeable. The attenuation increases by 0,2 dB beyond the 80 bendings and
is stable until 100 bendings
C) This test was performed on
a 9 m. cable, with minimum bending radius of 40mm. Before the test.
At 2.4 GHz
we have a higher loss of 0.2 dB while SRL and Impedance stability have no
variation.
Same situation until 60 bendings.
Händleranfragen für unsere Produkte erwünscht. |
Dealer enquiries wanted. We would like to prepare |
Si vous êtes commerçant(e), nous proposons de vous |
Per i commercianti abbiamo offerte speciali. |